How to handle Domino A120 inkjet printer viscosometer failure?
For general problems, for example, the viscometer has no value. It may be necessary to check whether the viscometer valve or the viscometer pipe, or the glass pipe in the viscometer is unblocked. If the viscosity value of the viscometer does not come out, generally, you should see whether the viscosity exceeds the standard. If it exceeds 255, it will not display. If it is lower than 40, it will not display whether the viscosity is low or high. First, see if the ink viscosity is too thin or too thick. Why is it too thick? Is the solvent not added? Is there a problem with the solvent valve? These should be taken into account. Because it is rarely caused by viscosity. Generally, it is put for a long time. It is relatively dry and sticks to the beads. At this time, poke the beads. Generally, this problem will be solved. The pipe rarely sticks because it is so thick: Unless you don’t use it for months, and then it is dried out, and there is always ink residue in the glass tube, the beads will not be detected. If the ink path is sealed and not dry, this problem is not easy to occur. For A120 and A220 machines, viscosity fault is the most common fault. For example, the valve is stuck, or the ink of the glass tube sticks to the steel ball, or the pipe is blocked, or the ink supply or which way is